LG AC Error Code List, A Step-by-Step Guide to Fix It
by C Hariharan | Updated Apr 21, 2023
LG ACs
LG ACs are one of the best ACs available on the market. The biggest advantage of LG air conditioners is their high energy savings, along with their higher speed and better cooling range when compared to conventional compressors. R32 refrigerant used in this AC has a lower global warming potential. The low refrigerant detection in the AC, in case of gas leakage or any other issue, will make the refrigerant level go below 40%, thus warning the user about it and shutting down the AC. Whenever someone thinks about an AC for their budget, it’s better to buy an LG AC. In the LG Air Conditioners, the throw distance of air is among the highest in the industry. LG provides a Gold Fin anti-corrosive condenser, which is resistant to corrosion and lengthens the life of the heat exchanger.
LG AC Error Code List
The following is the list of errors that could occur in the LG Air Conditioners.
Indoor Unit Faults
Error Code
Description
1
Indoor unit room temperature sensor error
2
Indoor unit inlet pipe sensor error
4
Float switch error (optional)
5
Communication error between indoor unit and outdoor units
6
Indoor unit outlet pipe sensor error
9
Indoor unit EPROM error
10
Indoor unit BLDC motor fan lock
12
Indoor unit middle pipe sensor error
Outdoor Unit Faults
Error Code
Causes
21
DC Peak (IPM Fault); Compressor DC voltage was too high
22
Current Transformed (CT2) error; Alternating current (AC) input too high
23
DC Link Low Volt
25
AC Low/High Volt
26
DC Comp Position Error (not providing rotation), Locking
27
PSC Fault; Current to inverter compressor between AC and DC converter circuit too high
28
Inverter compressor DC voltage is too high
29
Inverter compressor amperage is too high
31
Current-to-current transformer (CT) thermistor is too low
32
Inverter Compressor Discharge Pipe (D-Pipe) Overheat
40
CT Sensor Error; Thermistor is disconnected or shorted out
41
D-Pipe Sensor INV is disconnected or shorted out
44
Outdoor Air Sensor is disconnected or shorted out
45
Middle thermistor of outdoor unit condenser coil is disconnected or shorted out
46
Outdoor unit suction line thermistor is disconnected or shorted out
48
Outdoor unit coil outlet (liquid line) thermistor is disconnected or shorted out
53
Communication failure from outdoor unit to indoor unit
60
Outdoor unit printed circuit board (PCB) EPROM check sum error
61
Outdoor unit condenser coil temperature is too high
62
Outdoor unit inverter compressor PCB heat sink temperature is too high
63
Condenser coil pipe thermistor temperature is too low
65
Heat sink thermistor has disconnected or has shorted out
67
Outdoor brushless direct current (BLDC) fan motor lock error
Error Codes with Possible Causes
Error Code
Description
Causes
Check point and normal condition
1
Indoor air sensor
• Open / Short
• Soldered poorly
• Internal circuit errorNormal resistor: 10KS2/ at 25°C (Unplugged)
Normal voltage : 2.5Vdc / at 25°C (plugged)
2
Indoor inlet pipe sensor
• Open / Short
• Soldered poorlyNormal resistor: 5K£2/ at 25°C (Unplugged)
Normal voltage : 2.5Vdc / at 25°C (plugged)
6
Indoor outlet pipe sensor
• Internal circuit error
-
3
Communication
• Open / Short
• Connection of wire
3
Wired R/C
• Wrong connection
• Main PCB Volt. DC 12V
• Noise interference
4
Drain pump/Float switch
• Float switch Open. (Normal: short)
• The connection of wire(Drain pump/ Float switch)
• Drain pump power input. (220V)
• Drain tube installation.
• Indoor unit installation. (Inclination)
апр.53
Communication (Indoor - Outdoor)
• Communication poorly
• Power input AC 220V. (Outdoor, Indoor)
• The connector for transmission is disconnected.
• The connecting wires are misconnected.
• The GND1,2 is not connected at main GND.
• The communication line is shorted at GND.
• Transmission circuit of outdoor PCB is abnormal.
• Transmission circuit of indoor PCB is abnormal.
21
DC Peak
• Instant over current
• Over Rated current
• Poor insulation of IPM• An instant over current in the U,V,W phase
- Comp lock
- The abnormal connection of U,V,W
• Over load condition
- Overcharging of refrigerant
- Pipe length.
• Poor insulation of compressor
22
Max. C/T
Over current (14A)
Malfunction of compressor
Blocking of pipe
Low voltage input
Refrigerant, pipe length, blocked
40
CfT Internal circuit
Initial current error
Malfunction of current detection circuit.
(Open / Short)
The voltage of “C01N" Is 4.0Vdc(25A).
23
DC Link
• DC link volt, is 140Vdc.
• Check the power source.
23
Low voltage.
-
• Check the components.
28
DC Link High voltage
• DC link volt, is 420Vdc T
-
24
Press S/W Open
• Low / High press
• Check the connection of “CN_Press”.
• Check the components.
25
Input voltage
• Abnormal Input voltage
• Check the power source.
• Check the components.
26
DC Compressor Position
• Compressor position detect error
• Check the connection of comp wire “U,V,W”
• Malfunction of compressor
• Check the component of “IPM", detection parts.
27
PSC Fault
• Over current at "IGBT"
• Check the component of “IGBT".
• Check the components.
32
D-pipe (Inverter) temp, high (105°C t)
• Discharge sensor (Inverter) temp, high
• Check the discharge pipe sensor for INV.
• Check the install condition for over load.
• Check the leakage of refrigerant.
• Check the SVC V/V open.
33
D-pipe (Constant) temp, high (105°C I)
• Discharge sensor (Cons.) temp, high
• Check the discharge pipe sensor for Cons.
• Check the install condition for over load.
• Check the leakage of refrigerant.
• Check the SVC V/V open.
41
D-pipe sensor (Inverter)
• Open / Short
• Soldered poorly
• Internal circuit error• Normal resistor: 200K£2 / at 25°C (Unplugged)
• Normal voltage : 4.5Vdc / at 25°C (plugged)
44
Air sensor
-
• Normal resistor: 10K£2 / at 25°C (Unplugged)
• Normal voltage : 2.5Vdc / at 25°C (plugged)
45
Condenser Pipe sensor
-
• Normal resistor: 5K£2 / at 25°C (Unplugged)
46
Suction Pipe sensor
-
• Normal voltage : 2.5Vdc / at 25°C (plugged)
47
D-pipe sensor (Constant)
-
• Normal resistor: 200K£2 / at 25°C (Unplugged)
• Normal voltage : 4.5Vdc / at 25°C (plugged)
65
Heat sink sensor
-
• Normal resistor: 10K£2 / at 25°C (Unplugged)
• Normal voltage : 2.5Vdc / at 25°C (plugged)
51
Over capacity
• Over capacity
• Check the indoor unit capacity.
• Check the combination table.
60
EEPROM Check sum
• Check sum error
• Check the PCB ASM P/No.
• Check the poor soldering.
61
Condenser pipe sensor temp, high
• Condenser pipe sensor detected high temp.(65°C)
• Check the load condition.
• Check the sensor of Condenser pipe sensor.
62
Heat sink sensor temp, high
• Heat sink sensor detected high temp.(85°C)
• Check the fan is locked.
• Check the sensor of heat sink.
май.53
Title Communication (Indoor - Outdoor)
• Communication poorly
• Power input AC 220V. (Outdoor, Indoor)
• The connector for transmission is disconnected.
• The connecting wires are misconnected.
• The communication line is shorted at GND.
• Transmission circuit of outdoor PCB is abnormal.
• Transmission circuit of indoor PCB is abnormal.
21
DC PEAK (IPM Fault)
• Instant over current
• Over Rated current
• Poor insulation of IPM• An instant over current in the U,V,W phase
- Comp lock
- The abnormal connection of U,V,W
• Overload condition
- Overcharging of refrigerant
Pipe length.
Outdoor Fan is stop
• Poor insulation of compressor
LED Error Codes
Description
DC Link Peak (IPM Fault)
CT 2 (Max CT)
DC Link Low Volt. Low Voltage/Over Voltage
DC Compressor Position Error
PSC/PFC Fault Error
COMP Over Current
D-Pipe High
Low Pressure Error
Communication Error
CT Sensor (Open/Short)
INV. D-Pipe Th Error
High Pressure Sensor Error
Outdoor Air Th Error
Cond. Mid-Pipe Th Error
Suction Pipe Th Error
Cond. Out-Pipe Th Error
Capacity Over
Signal Error (Indoor Outdoor)
3-Phase Wrong wiring
EEPROM Check Sum Error
Cond. Pipe Th High
Heat sink Th High
Heat sink Th Error
Outdoor BLDC Fan Lock
PFC Fault Error(SAN)
Error Code
LED 01G/M (Red)
LED 01G/M (Red)
Causes
21
2 times 3
1 times 3
Over Rated Current
22
2 times 3
Input Over Current
23
DC Link High Volt.
3 times 3
DC Link Volt is below 140Vdc
DC Link Volt is above 420Vdc
25
5 times 3
Abnormal AC Volt Input
26
6 times 3
Compressor Starting Fall Error
27
7 times 3
Over Inverter PCB input current
29
9 times 3
Over Inverter Compressor Current
32
3 times 3
2 times 3
D-Pipe Temp. High
35
5 times 3
Excessive decrease of Low Pressure
39
9 times 3
Communication Error Between PFC Micom and INV Micom
40
4 times 3
0
CT Circuit Malfunction
41
1 times 3
Open/Short
43
3 times 3
44
4 times 3
45
5 times 3
46
6 times 3
48
8 times 3
51
5 times 3
1 times 3
Over combination
53
3 times 3
Communication Poorly
54
4 times 3
3-Phase Wrong Wring of Outdoor Unit (Reverse Phase/Omission of Phase)
60
6 times 3
0
Check Sum Mismatching
61
1 times 3
Cond. Temp. High
62
2 times 3
Heatsink Temp. High
65
5 times 3
Open/Short
67
7 times 3
Outdoor Fan is not operation
73
7 times 3
3 times 3
Over Current of Outdoor Unit PFC
Other Error Codes
Error Code
Code appears in the display. F1,F2 or F3
FL
CH01
Causes
Solution
Air conditioner is in FAN mode and the number shown is the set fan speed.
This is normal. The air conditioner is working properly.
The water collection tank is full.
Empty the water collection tank.
Short or open circuit in the indoor air thermistor.
Unplug the air conditioner and contact your authorized LG service center.
Error Code
Function Name
Description
01 h
Read Coil Status
Run/Stop(status), Lock(status), Swing(status), Alarm, Filter Sign(status), Mode Lock(status), Wind Flow Lock(status)
03h
Read Holding Registers
Operation Mode(status), Fan Speed(status), Room Temperature, Error Code, 05h
Force Single Coil
Run/Stop(setting), Lock(setting), Swing(setting), Filter Sign Reset, Mode Lock(setting), 06h
Preset Single Registers
Operation Mode(setting), Fan Speed(setting), Set Room Temperature(setting),
Set Room Temperature(status),
Set Lower Temperature(status),
Set Upper Temperature(status),
User Mode(status)
Wind Flow Lock(setting)
Set Lower Temperature(setting),
Set Upper Temperature(setting),
User Mode(setting)
LG Split AC Error Code List
Error Code
Description
LG AC error code po
System in power mode ( not a fault )
LG AC error code lo
System in test mode ( not a fault )
LG AC error code ch 01
Indoor unit return air thermistor
LG AC error code ch 02
Indoor unit coil inlet thermistor
LG AC error code ch 03
Wiring error between the remote controller and the fan coil
LG AC error code ch 04
Float switch fan
LG AC error code ch 05
Communication indoor and outdoor
LG AC error code ch 06
Indoor unit coil outlet thermistor
LG AC error code ch 09
EEPROM connects on main PCB
LG AC error code ch 10
Indoor fan motor problem
LG AC error code ch 21
Over current in the inverters DC power circuit
LG AC error code ch 22
Compressor over-current
LG AC error code ch 25
Incoming power supply to the system
LG AC error code ch 26
Inverter compressor
LG AC error code ch 27
Inverter module
LG AC error code ch 28
DC voltage inverter is too high
LG AC error code ch 29
Overload operation or compressor damage
LG AC error code ch 32
Inverter compressor discharge temperature is above 105 degrees
LG AC error code ch 39
PCB defect or wiring defect
LG AC error code ch 41
Inverter compressor discharge thermistor fault
LG AC error code ch 44
Outdoor unite air themermistor
LG AC error code ch 45
Condenser coil outlet thermistor
LG AC error code ch 46
Compressor suction thermistor
LG AC error code ch 47
Inverter compressor discharge thermistor fault
LG AC error code ch 61
Outdoor unit condenser coil temperature above 65 degrees
LG AC error code ch 62
Outdoor unit inverter heat-sink thermistor
LG AC error code ch 65
Inverter PCB heat sink thermistor
LG AC error code ch 67
Outdoor fan motor
LG AC error code ch 73
Overload operation or compressor damage
LG Inverter Air Conditioner Error Codes
Error Code
Description
LG AC error code c1 or ch1
Indoor temperature sensor open or closed circuit
LG AC error code c2 or ch2
Outdoor temperature sensor open or closed circuit
LG AC error code c4 or ch4
Heat sink temperature sensor open or closed circuit
LG AC error code c5 or ch5
Communication indoor and outdoor units
LG AC error code c6 or ch6
Excessive current at inverter DC power circuit
LG AC error code c7 or ch7
Excessive compressor current
LG AC error code c8 or ch8
Indoor fan not rotating
LG AC error code c9 or ch9
Outdoor fan not rotating
LG AC error code ca or ch10
Faulty discharge thermistor
LG AC error code cc
EEPROM error
LG AC error code cd
Inverter module error
LG AC error code po
System in power mode ( not a fault )
LG AC error code lo
System in test mode ( not a fault )
LG AC error code ch 01
Indoor unit return air thermistor
LG AC error code ch 02
Indoor unit coil inlet thermistor
LG AC error code ch 03
Wiring error between the remote controller and the fan coil
LG AC error code ch 04
Float switch fan
LG AC error code ch 05
Communication indoor and outdoor
LG AC error code ch 06
Indoor unit coil outlet thermistor
LG AC error code ch 09
EEPROM connects on main PCB
LG AC error code ch 10
Indoor fan motor problem
LG AC error code ch 21
Over current in the inverters DC power circuit
LG AC error code ch 22
Compressor over-current
LG AC error code ch 25
Incoming power supply to the system
LG AC error code ch 26
Inverter compressor
LG AC error code ch 27
Inverter module
LG AC error code ch 28
DC voltage inverter is too high
LG AC error code ch 29
Overload operation or compressor damage
LG AC error code ch 32
Inverter compressor discharge temperature is above 105 degrees
LG AC error code ch 39
PCB defect or wiring defect
LG AC error code ch 41
Inverter compressor discharge thermistor fault
LG AC error code ch 44
Outdoor unite air themermistor
LG AC error code ch 45
Condenser coil outlet thermistor
LG AC error code ch 46
Compressor suction thermistor
LG AC error code ch 47
Inverter compressor discharge thermistor fault
LG AC error code ch 61
Outdoor unit condenser coil temperature above 65 degrees
LG AC error code ch 62
Outdoor unit inverter heat-sink thermistor
LG AC error code ch 65
Inverter PCB heat sink thermistor
LG AC error code ch 67
Outdoor fan motor
LG AC error code ch 73
Overload operation or compressor damage
How to Fix The LG AC Error Code?
LG AC Error Code List - FAQs